Pre-configured or designed to your exact specifications

Allow us to be your trusted advisor for all your Data Centre Infrastructure needs from conceptual designs to turn key implementations.

Server Room Power and Rack N+1

$ 39,817.94 CAD
Call or Email for shipping details

Overview

  • An ideal Data Centre solution for small growing organizations with high availability requirements.

    Typical application requirements are low rack densities with N+1 power and cooling.

    Up to 40kW, this solution gives you the flexibility to scale your growth resulting in less oversizing and lower up-front expenditure. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS POWER
  • Output Power - 10kW Scalable to 40kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
  • Standard Warranty - 5 years repair or replace
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options

Overview

  • For Enterprise EDGE and low density Server Room applications. Typical application requirements are low rack densities with N+1 power for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace

Overview

  • For Enterprise EDGE and low density Server Room applications that require cooling.

    Typical application requirements are low rack densities with N+1 power and cooling for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, 5kW N+1 or 10kW of cooling, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace
INROW COOLING
  • Floor standing
  • Physical - 42U, Black, 1991H x 300W x 1069D mm
  • Up to 5kW Cooling Capacity
  • Warranty - 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up
  • INROW COOLING START UP AND INSTALLATION
  • Quickly and efficiently implement your InRow Cooling

Overview

  • High availability solution for organizations requiring medium to high density in a small footprint.

    Typical application requirements are 5kW to 10kW rack densities with N+1 or optional 2N power and cooling.

    Up to 100kW, this solution provides ample power and cooling to seamlessly run demanding IT loads. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included. The Hot Aisle Containment System dramatically increases cooling efficiency and reduces hot spots. According to APC, you can save up to 40% in annual cooling system energy cost versus traditional raised floor cooling.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS Power
  • Output Power - 10kW Scalable to 100kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options
IN STOCK :
0

Server Room Power, Rack, Cooling N+1

$ 67,303.64 CAD
Call or Email for shipping details

Overview

  • An ideal Data Centre solution for small growing organizations with high availability requirements.

    Typical application requirements are low rack densities with N+1 power and cooling.

    Up to 40kW, this solution gives you the flexibility to scale your growth resulting in less oversizing and lower up-front expenditure. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS POWER
  • Output Power - 10kW Scalable to 40kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
  • Standard Warranty - 5 years repair or replace
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options

Overview

  • For Enterprise EDGE and low density Server Room applications. Typical application requirements are low rack densities with N+1 power for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace

Overview

  • For Enterprise EDGE and low density Server Room applications that require cooling.

    Typical application requirements are low rack densities with N+1 power and cooling for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, 5kW N+1 or 10kW of cooling, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace
INROW COOLING
  • Floor standing
  • Physical - 42U, Black, 1991H x 300W x 1069D mm
  • Up to 5kW Cooling Capacity
  • Warranty - 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up
  • INROW COOLING START UP AND INSTALLATION
  • Quickly and efficiently implement your InRow Cooling

Overview

  • High availability solution for organizations requiring medium to high density in a small footprint.

    Typical application requirements are 5kW to 10kW rack densities with N+1 or optional 2N power and cooling.

    Up to 100kW, this solution provides ample power and cooling to seamlessly run demanding IT loads. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included. The Hot Aisle Containment System dramatically increases cooling efficiency and reduces hot spots. According to APC, you can save up to 40% in annual cooling system energy cost versus traditional raised floor cooling.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS Power
  • Output Power - 10kW Scalable to 100kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options
IN STOCK :

Overview

  • An ideal Data Centre solution for small growing organizations with high availability requirements.

    Typical application requirements are low rack densities with N+1 power and cooling.

    Up to 40kW, this solution gives you the flexibility to scale your growth resulting in less oversizing and lower up-front expenditure. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS POWER
  • Output Power - 10kW Scalable to 40kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
  • Standard Warranty - 5 years repair or replace
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options

Overview

  • For Enterprise EDGE and low density Server Room applications. Typical application requirements are low rack densities with N+1 power for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace

Overview

  • For Enterprise EDGE and low density Server Room applications that require cooling.

    Typical application requirements are low rack densities with N+1 power and cooling for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, 5kW N+1 or 10kW of cooling, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace
INROW COOLING
  • Floor standing
  • Physical - 42U, Black, 1991H x 300W x 1069D mm
  • Up to 5kW Cooling Capacity
  • Warranty - 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up
  • INROW COOLING START UP AND INSTALLATION
  • Quickly and efficiently implement your InRow Cooling

Overview

  • High availability solution for organizations requiring medium to high density in a small footprint.

    Typical application requirements are 5kW to 10kW rack densities with N+1 or optional 2N power and cooling.

    Up to 100kW, this solution provides ample power and cooling to seamlessly run demanding IT loads. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included. The Hot Aisle Containment System dramatically increases cooling efficiency and reduces hot spots. According to APC, you can save up to 40% in annual cooling system energy cost versus traditional raised floor cooling.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS Power
  • Output Power - 10kW Scalable to 100kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options
IN STOCK :

Overview

  • An ideal Data Centre solution for small growing organizations with high availability requirements.

    Typical application requirements are low rack densities with N+1 power and cooling.

    Up to 40kW, this solution gives you the flexibility to scale your growth resulting in less oversizing and lower up-front expenditure. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS POWER
  • Output Power - 10kW Scalable to 40kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
  • Standard Warranty - 5 years repair or replace
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options

Overview

  • For Enterprise EDGE and low density Server Room applications. Typical application requirements are low rack densities with N+1 power for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace

Overview

  • For Enterprise EDGE and low density Server Room applications that require cooling.

    Typical application requirements are low rack densities with N+1 power and cooling for switches, PBX and entry level servers.

    Up to 16kVA, this solution provides the necessary ups power, 5kW N+1 or 10kW of cooling, rack, power distribution with network management capabilities.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS
  • Output Power - 16kVA, 12.8kW Configurable for 120/208 or 120/240 output voltage
  • Runtime - Full load 5 min 57 sec, Half load 17 min 5 sec, Scalable
  • Outlets - (1) Hard wire 4-wire (2P + N + E), (8) NEMA L5-20R, (4) NEMA L14-30R (All Battery Backup)
  • Standard Warranty - 2 years repair or replace
RACK
  • Floor standing
  • Physical - 42U, Black, 1991H x 600W x 1070D mm
  • Baying hardware, Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
  • Guaranteed compatibility with all EIA-310 compliant 19" equipment
  • Standard Warranty - 5 years repair or replace
RACK PDU
  • Network manageable, metered , alarm thesholds, power utilization data
  • Power - 120V, 20A
  • Outlets - (24) NEMA 5-20R
  • Input Connector - NEMA L5-20P
  • Standard Warranty - 2 years repair or replace
INROW COOLING
  • Floor standing
  • Physical - 42U, Black, 1991H x 300W x 1069D mm
  • Up to 5kW Cooling Capacity
  • Warranty - 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up
  • INROW COOLING START UP AND INSTALLATION
  • Quickly and efficiently implement your InRow Cooling

Overview

  • High availability solution for organizations requiring medium to high density in a small footprint.

    Typical application requirements are 5kW to 10kW rack densities with N+1 or optional 2N power and cooling.

    Up to 100kW, this solution provides ample power and cooling to seamlessly run demanding IT loads. All the necessary ups power, rack, power distribution, cooling and management infrastructure is included. The Hot Aisle Containment System dramatically increases cooling efficiency and reduces hot spots. According to APC, you can save up to 40% in annual cooling system energy cost versus traditional raised floor cooling.

    Our designers will work with you to simplify the engineering, planning and construction thus reducing the total time from concept to completion. Advanced design tools and strategies allow your technology investment to align with business requirements.

Quick Specs

UPS Power
  • Output Power - 10kW Scalable to 100kW N+1, Input 208V 3 Phase, Output 120/208V
  • Scalable Runtime
  • Two (2) Metered Power Distribution units per rack with 120/208V
  • Green Premium Eco-Mark
COOLING
  • In Row Direct Expansion or Chilled Water
  • Physical - 42U, Black, 1991H x 300W x 1070D mm
  • 208/240/480V Input
  • Outdoor Condenser and Accessories
RACK, MONITORING AND MANAGEMENT
  • 42U Enclosures for Servers and Networking. Guaranteed compatibility with EIA-310 19" equipment
  • Netbotz Security and Environmental Monitoring of Temperature, Humidity, Water, Smoke, Cameras and other optional sensors
  • DCIM Software
  • Installation and Start Up Services
  • Preventative Maintenance, Warranty and Remote Monitoring Options
IN STOCK :

Pre-Configured or Designed Data Center Solutions