Symmetra PX 100kW Scalable to 100kW, 208V with Startup
Can’t find exactly what you’re looking for?
Give us a call at 905-839-7496, and we’ll be happy to assist you!
$9,432.88
Symmetra PX 100kW Scalable to 100kW, 208V with Startup
Energy Efficient
Main Documents
Documents
Presentation | A modular, high-efficiency 3-phase UPS that is scalable up to 100kW. Suitable for use in small to medium data centres and high density zones. |
---|---|
Lead time | Usually Ships within 3 Weeks |
100% |
|
Main Input Voltage | 208 V 3 phase |
Main Output Voltage | 120 V 208 V 208 V 3 phase |
Rated power in W | 100000 W |
Rated power in VA | 100000 VA |
Output connector type | Hard Wire 5-wire (3P + N + E) 1 |
Battery Type | VRLA |
Provided equipment | Installation guide Network Management Card Start-Up Service User Manual |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Number of battery filled slots | 9 |
Number of battery free slots | 0 |
Battery recharge time | 2 h |
Battery voltage | +/- 192 V (split battery referenced to neutral) |
Discharge battery voltage | +/- 154 V |
Maximum short-circuit current | 30 kA |
Max current discharge | 351 A |
Battery charger power | 15475 W rated |
Battery design life | 5…8 year(s) |
Extended runtime | 0 |
Number of power module free slots | 0 |
---|---|
Number of power module filled slots | 10 |
Redundant | Yes |
Colour | Black |
---|---|
height | 79.17 in (201.1 cm) |
Width | 47.24 in (120 cm) |
Depth | 42.13 in (107 cm) |
Net weight | 4232.88 lb(US) (1920 kg) |
USB compatible | No |
Network frequency | 40…70 Hz |
---|---|
Input voltage limits | 177…239 V 208 V |
Maximum input current | 332 A |
Input harmonic distortion | Less than 5 % for full load |
Load power factor | 0.5 leading to 0.5 lagging |
Input Power Factor at Full Load | 0.99 |
Maximum configurable power in W | 100000 W |
---|---|
Harmonic distortion | Less than 2 % |
Output frequency | 57…63 Hz for 60 Hz nominal sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
UPS type | Double conversion online |
Wave type | Sine wave |
Output voltage tolerance | +/- 1% static and +/- 5% at 100% load step |
Output harmonic distortion | < 2% for 0 to 100% linear load and < 6% for full non-linear load |
Bypass type | Built-in static bypass |
Efficiency | 94.7 % in battery operation) |
Maximum configurable power in VA | 100000 VA |
Transfer time | 2 ms typical |
Standards | CSA C22.2 No 107.3-05 FCC part 15 class A ISO 14001 ISO 9001 UL 1778 |
---|
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0…3333 ft |
Ambient air temperature for storage | 5…104 °F (-15…40 °C) |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic level | 67 dBA |
NEMA degree of protection | NEMA 1 |
Free slots | 2 |
---|---|
Preinstalled device | Network management card with CAN |
Control panel | Multifunction LCD status and control console |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 84.25 in (214 cm) |
Package 1 Width | 47.64 in (121 cm) |
Package 1 Length | 66.77 in (169.6 cm) |
Package 1 Weight | 4655.77 lb(US) (2111.82 kg) |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|